Oxygen / Nitrogen / Hydrogen Analyzer ELEMENTRAC ON-p
Price :
Quick contact
The ELEMENTRAC ON-p determines oxygen and nitrogen in inorganic samples by inert gas fusion in an impulse furnace with temperatures in excess of 3,000 °C.
The ELEMENTRAC ON-p guarantees precise and fast sample analysis. The analyzer covers a wide range of applications such as metal, ceramics and other inorganic materials.
The ELEMENTRAC ON-p can be supplied with up to two infrared cells with different path lengths, accommodating both high and low level oxygen analysis. Nitrogen concentrations are determined in the ELEMENTRAC ON-pby a robust and sensitive thermal conductivity cell.
Application Examples
alloys, cast iron, ceramics, copper, refractory metals, steel, ...
Producer : ELTRA - GERMANY
Product Advantages
simultaneous nitrogen and oxygen determination with inert gas fusion technique
NEW: closed gas management and optimized gas circulation for sensitive ON determination
NEW: use of cost efficient argon as carrier gas possible
NEW: powerful catalyst furnace for precise oxygen measurement
NEW: gas flow system with electronic gas flow control and new leakage test
NEW: water-cooled sample port system for effective removal of atmospheric gases
flexible configurations and measuring ranges for O and N
high sensitivity IR and TC cells with low detection limits
short analysis time
powerful 8,5 kW* impulse furnace for temperatures in excess of 3,000 °C
NEW: chemicals and tubes are hidden behind a door (removable)
NEW: powerful software supporting data and application export, with comment fields
single and multipoint calibration (linear regression)
NEW: cooling via tap water, heat exchanger or chiller
New design allows operation in production control and laboratory
Features
Measured elements | nitrogen, oxygen |
Samples | inorganic |
Furnace alignment | vertical |
Sample carrier | graphite crucibles |
Field of application | ceramics, engineering / electronics, steel / metallurgy |
Furnace | electrode impulse furnace (max. 8,5 KW*), temperatures in excess of 3,000 °C |
Detection method | solid state infrared absorption for oxygen thermal conductivity for nitrogen |
Typical analysis time | 120 - 180 s |
Chemicals required | copper oxide, magnesium perchlorate, sodium hydroxide |
Gas required | compressed air, helium 99.995 % pure, argon 99.995% pure (if required), all gases with (2 - 4 bar / 30 - 60 psi) |
Power requirements | 3~ 400 V, 50/60 Hz, max. 8,500 W |
Dimensions (W x H x D) | 57 x 77 x 63 cm |
Weight | ~ 161 kg |
Required equipment | balance (resolution 0.0001g), monitor, PC |
Optional accessories | carrier gas purification, external chiller, gas calibration unit |
- | * limited to 6.8 kw in application settings |